Electrical FAQs
13-
Electrical FAQs
Smoke detectors are required in all bedrooms, hallway outside of bedroom, one on each floor.
-
Electrical FAQs
Carbon Monoxide Detectors are required in bedroom hallways.
-
Electrical FAQs
A ground rod wire never has to be larger than a Number 4 copper. It cannot be smaller than Number 4 if it is subject to physical damage.
-
Electrical FAQs
The size is Number 4 copper or Number 2 aluminum.
-
Electrical FAQs
The size is Number 2-O copper or Number 4-O aluminum.
-
Electrical FAQs
The GFCI outlet must be at least 5 feet from the inside wall.
-
Electrical FAQs
Street lights are not our jurisdiction, call Ohio Edison at 800-633-4766. We only maintain Traffic signals.
-
Electrical FAQs
PVC conduit must be 18 inches deep.
-
Electrical FAQs
Yes, but they must be type S so a larger fuse cannot be installed.
-
Electrical FAQs
They are required in all:
- Baths
- Garages
- Kitchen Counters
- Outbuildings
- Outside
- Pools
- Unfinished basements
-
Electrical FAQs
It means arc fault circuit interrupter.
-
Electrical FAQs
It trips on inline arcs such as broken ripcords, loose connections, etc.
-
Electrical FAQs
The water ground connection has to be within 5 feet of the water service entering the house.